Externally Mounted Ventilators – Install Quick Specs
VEN100E
Installation Type & Discharge Direction
Ventilator Carton Weight:
Mounted outside. Can be mounted on exterior
roof or wall.
VEN100E = 80 lbs.
CFM Rating
1000 CFM = VEN100E
Minimum Duct Size
10” round
7"
Maximum Equivalent Straight Duct Length
4"
50 feet
Equivalent Straight Lengths
•
•
•
•
•
1 foot of 8” or 10” duct = 1 foot
1 foot of 3 ¼” x 14” rectangular = 1 foot
8” round 90 degree Elbow = 5 feet
10” round 90 degree Elbow = 3 feet
Wall or Roof Cap = 2 feet
VEN100E
Standard Features
U
U
L
L
LISTED7Z66
C
•
•
Adaptable to all Wind Crest hoods
Weather-resistant galvanized steel
construction
•
•
Thermally protected, permanently
lubricated motor
Dynamically balanced 11” diameter blower
wheel
•
•
•
Neoprene resilient anti-vibration mounted
Built-in Flashing plate for roof or wall mount
Easily removed blower cover for periodic
cleaning
Ventilator Motor Ratings*
Hoods without Heat Lamps:
8.0 Amps @ 120 V AC, 60 Hz
Hoods with Heat Lamps:
12.4 Amps @ 120 V AC, 60 Hz
*For maximum power supply required, refer to
hood series selected.
Copyright 2006 Wind Crest by CNP Industries
1
Install Quick Specs are for planning purposes only. Please refer to the detailed installation
instructions, prior to making any cutouts.
|
Well Traveled Living Fire Pit 60454 User Manual
Weslo Treadmill WLTL24090 User Manual
Windsor Vacuum Cleaner SRS12 User Manual
Winegard Satellite TV System RM DM61 DM55 User Manual
Wolfcraft Drill 4525 User Manual
Xantrex Technology Power Supply ACCB User Manual
Xerox Computer Monitor XM7 19w User Manual
Xerox Printer WorkCentre 3655 S User Manual
XO Vision Tablet EGP008BL User Manual
Yamaha Music Mixer DMP9 16 User Manual